SikaTack® Panel-50
1-component silicone for panel bonding in ventilated facades
SikaTack® Panel-50 is a non-sag, 1-component silicone of paste-like consistency for structural joints in ventilated facades and interior wall cladding between the vertically installed substructure and the panel that will be subjected to dynamic and static stresses and elevated facade temperatures. It cures on exposure to atmospheric humidity to form a durable elastomer. SikaTack® Panel-50 is part of the SikaTack® Panel system for the economic, concealed fixing of ventilated facades.
- Carries ETA 19/0511, Adhesive for wall cladding by ITeC
- Elastic fixing system, vibration and movement absorbing
- Provides creative opportunities for facade design
- Withstands high dynamic and static stresses and elevated facade temperatures
- Uniform tension over the whole facade
panel (no stress points) - 1-component product, ready to use
- Outstanding UV and weathering resistance
- Bonds well to a wide variety of substrates
- Complies with common VOC requirements:
Indoor Air Comfort GOLD: pass, EMICODE:
EC1 Plus, French VOC Regulation: A+,
BREEAM International (v.6 2021)/BREEAM
NOR (v.6 2022): Exemplary Level, M1: pass,
Global LEED v4/v4.1 beta EQc 2: Low-Emit-
ting Materials: CDPH-IAQ SCAQMD Rule 1168 - IBU Environmental Product Declaration (EPD) available
PRODUCT BENEFITS
- Carries ETA 19/0511, Adhesive for wall cladding by ITeC
- Elastic fixing system, vibration and movement absorbing
- Provides creative opportunities for facade design
- Withstands high dynamic and static stresses and elevated facade temperatures
- Uniform tension over the whole facade
panel (no stress points) - 1-component product, ready to use
- Outstanding UV and weathering resistance
- Bonds well to a wide variety of substrates
- Complies with common VOC requirements:
Indoor Air Comfort GOLD: pass, EMICODE:
EC1 Plus, French VOC Regulation: A+,
BREEAM International (v.6 2021)/BREEAM
NOR (v.6 2022): Exemplary Level, M1: pass,
Global LEED v4/v4.1 beta EQc 2: Low-Emit-
ting Materials: CDPH-IAQ SCAQMD Rule 1168 - IBU Environmental Product Declaration (EPD) available
Areas of Application
SikaTack® Panel-50 is suitable for structural joints in ventilated facades and cladded interior walls between the vertically installed substructure and the facade panel that will be subjected to dynamic and static stresses and even elevated facade temperatures. Suitable substrates are anodized and coated aluminum, glass, metal composite, high pressure laminate and ceramic materials. This product is suitable for experienced professional users only. Tests with actual substrates and conditions have to be performed ensuring adhesion and material compatibility.Product Details
Chemical base | 1-component silicone | |
Color (CQP001-1) | Grey | |
Cure mechanism | Moisture-curing | |
Density (uncured) | 1.4 kg/l | |
Non-sag properties (CQP061-4 / ISO 7390) | Good | |
Application temperature | ambient | 5 ─ 40 °C |
Skin time (CQP019-1) | 25 minutes A | |
Curing speed (CQP049-1) | (See diagram) | |
Shore A hardness (CQP023-1 / ISO 48-4) | 38 | |
Tensile strength (CQP036-1 / ISO 527) | 2.1 MPa | |
Elongation at break (CQP036-1 / ISO 527) | 450 % | |
Tear propagation resistance (CQP045-1 / ISO 34) | 7 N/mm | |
Service temperature | -40 ─ 150 °C | |
Shelf life | 9 months B |
CQP = Corporate Quality Procedure | A) 23 °C / 50 % r. h. | B) storage below 25 °C |
CURE MECHANISM
SikaTack® Panel-50 cures by reaction with atmospheric moisture. At low temperatures the water content of the air is generally lower and the curing reaction proceeds some-what slower (see diagram 1).
Diagram 1: Curing speed SikaTack® Panel-50
Application
Surface preparation
Surfaces must be clean, dry and free from grease, oil and dust. Surface treatment depends on the specific nature of the substrates and is crucial for a long lasting bond.
Application
The standard geometry for bonding façade panels is at least 12 x 3 mm. The supplied nozzle (10 x 8 mm) ensures proper dimension of the compressed bead (see figure below).
Figure 1: Recommended bead configuration
The optimum temperature for substrate and adhesive is between 15 °C and 25 °C. Do not apply at temperatures below 5 °C or above 40 °C.
To avoid condensation on the surfaces, the temperature of the bonding components (e.g. façade panels, sub-frames) must be at least 3 °C higher than the dew point of the air.
The skin time is significantly shorter in hot and humid climate. The panel must always be installed within 75 % of the skin time determined under local climate conditions (see General Guideline “SikaTack® Panel System”). Never join bonding parts if the adhesive has built a skin. SikaTack® Panel-50 can be processed with hand, pneumatic or electric driven piston guns.
Removal
Uncured SikaTack® Panel-50 can be removed from tools and equipment with Sika® Remover-208 or another suitable solvent. Once cured, the material can only be removed mechanically.
Hands and exposed skin have to be washed immediately using hand wipes such as Sika® Cleaner-350H or a suitable industrial hand cleaner and water.
Do not use solvents on skin.
Application limits
SikaTack® Panel-50 used for panel bonding is always used in conjunction with SikaTack® Panel Fixing Tape. SikaTack® Panel Fixing Tape ensures the correct joint thickness and keeps the bonded panels initially in place. By curing SikaTack® Panel-50 builds up strength and takes over the long-term load bearing.
SikaTack® Panel Fixing Tape is not a structural component.