SikaBiresin® TC-455
2-component compressible gap filler for heat transfer
SikaBiresin® TC-455 is a 2-component compressible gap filler with high thermal conductivity based on silane-terminated polymers (STP). It is silicone free and cures at room temperature.
- High thermal conductivity
- Easy compressible to thin layers
- Flame retardant and self extinguishing
- Easy to remove for repair work
- Silicone free
Overview
PRODUCT BENEFITS
- High thermal conductivity
- Easy compressible to thin layers
- Flame retardant and self extinguishing
- Easy to remove for repair work
- Silicone free
Areas of Application
SikaBiresin® TC-455 is suitable for gap filler applications between two surfaces to ensure a proper thermal management of the bonded parts, e.g. for EV battery boxes. This product is suitable for professional experienced users only. Tests with actual substrates and conditions have to be performed ensuring adhesion and material compatibility.Packaging
SikaBiresin® TC-455 A+B
| Dual cartridge | 400 ml |
| Mixer: Nordson TAH 7701816 |
SikaBiresin® TC-455 (A)
| Pail | 23 l |
| Drum | 180 l |
SikaBiresin® TC-455 (B)
| Pail | 23 l |
| Drum | 180 l |
Product Details
| Properties |
| ||||
| Chemical base | 2-component silane terminated polymer (STP) | ||||
| Color (CQP001-1) |
| ||||
| Consistency |
| ||||
| Density (uncured) |
mixed |
| |||
| Mixing ratio | A : B by volume | 1 : 1 | |||
| Viscosity (CQP029-4) |
mixed |
| |||
| Application temperature | 20 ─ 40 °C | ||||
| Open time (CQP046-11 / ISO 4587) | 60 minutes | ||||
| Shore A hardness (CQP023-1 / ISO 48-4) | 35 | ||||
| Thermal conductivity (ASTM D5470) | 2.2 W/(mK) B | ||||
| Flammability (UL 94-2013 Rev.7-2017 s.8) | V0 | ||||
| Tensile strength (CQP036-2 / ISO527-2) | 0.5 MPa C | ||||
| Elongation at break (CQP036-2 / ISO 527-2) | 20 % | ||||
| Service temperature (CQP509-1 / CQP513-1) | -40 ─ 90 °C | ||||
| Shelf life | 6 months |
| CQP = Corporate Quality Procedure | A) with PP 25 mm at 10 s-1, thickness: 0.5 mm | B) at 25 °C , thickness: 2 mm |
| C) cured for 7 days at 23 °C / 50 % r.h. |
CURE MECHANISM
The curing of SikaBiresin® TC-455 takes place by a chemical reaction of the two components. Higher temperatures speed up the curing process and lower slow it down.
Application
Surface preparation
Surfaces must be clean, dry and free from grease, oil, dust and contaminants.
All pre-treatment steps must be confirmed by preliminary tests on original substrates considering specific process conditions.
Application
SikaBiresin® TC-455 can be dispensed from dual cartridges with a suitable pneumatic or electrical dispenser or with an adequate 2-component equipment.
Cartridge: Extrude adhesive without mixer to equalized the filling levels. Attach the mixer and dispose of the first few centimeters of the bead before the application. The specified mixer must be used to ensure good mixing quality. Other static mixers may be suitable but have to be thoroughly tested beforehand.
Bulk: If SikaBiresin® TC-455 is dispensed from pails or drums with an 2-component equipment, the mixer must be defined by preliminary tests under production conditions.
For advice on selecting and setting up a suitable pump system, contact the System Engineering Department of Sika Industry.
Removal
Uncured SikaBiresin® TC-455 may be removed from tools and equipment with Sika® Remover-208. Once cured, the material can only be removed mechanically.
Hands and exposed skin have to be washed immediately using hand wipes such as Sika® Cleaner-350H or a suitable industrial hand cleaner and water.
Do not use solvents on skin.
STORAGE CONDITIONS
SikaBiresin® TC-455 has to be kept between 5 °C and 25 °C in a dry place. Do not expose it to direct sunlight or frost.
After opening of the packaging, the content has to be protected against humidity.
Consider, that the cartridges must be stored horizontally.